Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 81 Warning: fopen(/home/virtual/neurointervention/journal/upload/ip_log/ip_log_2024-05.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 83 Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 84 Rescue Balloon Reposition of the Protruding Coil Loops during Endovascular Treatment of An Anterior Communicating Artery Aneurysm: A Case Report.
Neurointervention Search

CLOSE


Neurointervention 2006;1(1):68-72.
Rescue Balloon Reposition of the Protruding Coil Loops during Endovascular Treatment of An Anterior Communicating Artery Aneurysm: A Case Report.
Hong Gee Roh, Hyun Seung Kang, Pyoung Jeon, Hong Sik Byun
1Department of Radiology, Konkuk University Hospital, Seoul, Korea.
2Department of Neurosurgery, Konkuk University Hospital, Seoul, Korea.
3Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea. hsbyun@smc.samsung.co.kr
Abstract
Protrusion of coil loop(s) and subsequent occlusion of the parent artery is one of the dreadful complications during endovascular coil embolization of cerebral aneurysm. Although protrusion of one or two coil loops may not cause adverse events and can be ignored in many instances, it can also compromise the parent artery in some cases with or without thrombus formation. We report a case of rescue balloon reposition of the protruding coil mass back into the aneurysm and recanalization of parent artery during embolization of the anterior communicating artery aneurysm.
Key Words: Cerebral aneurysm; Complication; Endovascular treatment; Detachable coil; Balloon
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 14,759 View
  • 20 Download
Related article in NI

Endovascular Treatment of Idiopathic Intracranial Hypertension: A Case Report.2009 February;4(1)



ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
#705-2C, 9 Gangnam-ro, Giheung-gu, Yongin-si, Gyeonggi-do 16977, KOREA
Tel: +82-31-994-4382    Fax: +82-2-2275-9198    E-mail: editor@neurointervention.org                

Copyright © 2024 by Korean Society of Interventional Neuroradiology.

Developed in M2PI

Close layer
prev next