Optimization of MR Parameters of 3D TOF-MRA for Various Intracranial Stents at 3.0T MRI
Jin Woo Choi, Hong Gee Roh, Won-Jin Moon, Young Il Chun, Chung Hwan Kang
Neurointervention. 2011;6(2):71-77. Published online 2011 Aug 31 DOI: https://doi.org/10.5469/neuroint.2011.6.2.71
|
Citations to this article as recorded by
Safety and efficacy of the novel Alpha stent for the treatment of intracranial wide-necked aneurysm
Junhyung Kim, Jung-Jae Kim, Seung Won Kim, Jinyoung Choi, Hanki Kim, Jinwoo Kim, Joonho Chung
Scientific Reports.2024;[Epub] CrossRef Impact of Various Non-Contrast-Enhanced MRA Techniques on Lumen Visibility in Vascular Flow Models with a Surpass Evolve Flow Diverter
Yigit Ozpeynirci, Margarita Gorodezky, Augusto Fava Sanches, Sagar Mandava, Ana Beatriz Solana, Thomas Liebig
Diagnostics.2024; 14(11): 1146. CrossRef Comparison of the imaging performance of time-of-flight MRA and ultrashort echo time MRA in flow diverters: A phantom study
Toshiya Akatsu, Akihiko Wada, Michimasa Suzuki, Haruyuki Fukuchi, Yutaka Ikenouchi, Nao Takano, Fumihiro Yagisawa, Kosuke Teranishi, Akira Ishii, Akihide Kondo, Shigeki Aoki
Interventional Neuroradiology.2024;[Epub] CrossRef Intracranial aneurysms treated with stent-assisted coil embolization: evaluation with four-dimensional ultrashort-TE MR angiography
Hiroyuki Uetani, Mika Kitajima, Yuki Ohmori, Kosuke Morita, Yuichi Yamashita, Yasuyuki Kaku, Takeshi Nakaura, Akira Sasao, Goh Sasaki, Soichiro Ishiuchi, Akitake Mukasa, Toshinori Hirai
European Radiology.2023; 33(11): 7923. CrossRef Assessment of Lower Limb Artery Stent Placement with 3D Variable Refocusing Flip Angle Turbo Spin Echo : A Report on Two Cases
Yuki SHIMADA, Michiaki HIGASHITANI, Junichi HASHIMOTO, Akio TSUMURAYA
Japanese Journal of Magnetic Resonance in Medicine.2023; 43(4): 182. CrossRef Usefulness of Silent Magnetic Resonance Angiography in the Follow-Up of Endovascular-Treated Intracranial Aneurysm: A Prospective Study
Song Tan, Yuzhao Lu, Bin Li, Qin Wu, Xiaobing Zhou, Yang Wang
Journal of Stroke and Cerebrovascular Diseases.2022; 31(2): 106256. CrossRef Usefulness of Silent MRA for Evaluation of Aneurysm after Stent-Assisted Coil Embolization
You Na Kim, Jin Wook Choi, Yong Cheol Lim, Jihye Song, Ji Hyun Park, Woo Sang Jung
Korean Journal of Radiology.2022; 23(2): 246. CrossRef MRI-Compatible Microcirculation System Using Ultrasonic Pumps for Microvascular Imaging on 3T MRI
Ju-Yeon Jung, Dong-Kyu Seo, Yeong-Bae Lee, Chang-Ki Kang
Sensors.2022; 22(16): 6191. CrossRef Comparison of 3D T1-SPACE and DSA in evaluation of intracranial in-stent restenosis
Qiuji Shao, Qiang Li, Qiaowei Wu, Tianxiao Li, Li Li, Kaitao Chang
The British Journal of Radiology.2021;[Epub] CrossRef Application of 3D T1-SPACE combined with 3D-TOF sequence for follow-up evaluation of stent-assisted coil embolization for intracranial aneurysm
Qiuji Shao, Qiang Li, Qiaowei Wu, Tianxiao Li, Li Li, Kaitao Chang, Yingkun He
Journal of Interventional Medicine.2021; 4(2): 71. CrossRef Imaging Parameter Optimization of 3D Radial Stack-of-stars MRA with FID Sampling after Treatment of Cerebral Aneurysms with Metallic Devices
Daichi Murayama, Takayuki Sakai, Masami Yoneyama, Kiichi Nose, Hidehisa Hatakeyama, Kazutoshi Watanabe, Shigehiro Ochi
Japanese Journal of Radiological Technology.2021; 77(6): 572. CrossRef Form and Function in Intracranial Neurovascular Stents: A Historical Perspective and State-of-the-Art Clinical Review for the Noninterventionalist
M.T. Caton, A.Z. Copelan, K.H. Narsinh, D. Murph, A. A. Abla, D.L. Cooke, S.W. Hetts, V.V. Halbach, C.F. Dowd, R.T. Higashida, M.R. Amans
Neurographics.2021; 11(2): 96. CrossRef Usefulness of Noncontrast-Enhanced Silent Magnetic Resonance Angiography (MRA) for Treated Intracranial Aneurysm Follow-up in Comparison with Time-of-Flight MRA
Kyeong Hwa Ryu, Hye Jin Baek, Jin Il Moon, Bo Hwa Choi, Sung Eun Park, Ji Young Ha, Hyun Park, Seung Soo Kim, Jung-Soo Kim, Soo Buem Cho, Michael Carl
Neurosurgery.2020; 87(2): 220. CrossRef Magnetic Resonance Imaging of Venous Stents at 1.5 T
Simon Reiss, Ali Caglar Özen, Thomas Lottner, Andreas Reichert, Alexander Massmann, Michael Bock
Investigative Radiology.2020; 55(11): 741. CrossRef Neurovascular stent artifacts in 3D‐TOF and 3D‐PCMRI: Influence of stent design on flow measurement
Pierre Bouillot, Olivier Brina, Bénédicte M. A. Delattre, Rafik Ouared, Alain Pellaton, Hasan Yilmaz, Paolo Machi, Karl‐Olof Lovblad, Mohamed Farhat, Vitor Mendes Pereira, Maria Isabel Vargas
Magnetic Resonance in Medicine.2019; 81(1): 560. CrossRef Pointwise Encoding Time Reduction with Radial Acquisition with Subtraction-Based MRA during the Follow-Up of Stent-Assisted Coil Embolization of Anterior Circulation Aneurysms
Y.J. Heo, H.W. Jeong, J.W. Baek, S.T. Kim, Y.G. Jeong, J.Y. Lee, S.-C. Jin
American Journal of Neuroradiology.2019; 40(5): 815. CrossRef Visualization of Four Intracranial Stents and In-stent Stenosis with Stenotic Models by 3D-TOF-MRA
Takuma Hayashi, Atsushi Fukuda
Japanese Journal of Radiological Technology.2019; 75(8): 747. CrossRef Imaging Parameter Optimization of Non-contrast Three-dimensional Time-of-flight Magnetic Resonance Angiography for Patients with Intracranial Stents Using a 1.5 T Magnetic Resonance Imaging System
Toshiya Akatsu, Yoshiyuki Ishimori, Tomoya Kobayashi, Katsumi Miyamoto
Japanese Journal of Radiological Technology.2019; 75(12): 1437. CrossRef Blood Flow Assessment of the Neck-bridged Stent Lumen after Stent-assisted Coiling Using 3D-TOF MRA
Nobuyuki Mitsui, Kouji Kubota, Naoto Izumi, Hajime Wada
Journal of Neuroendovascular Therapy.2018;[Epub] CrossRef Does stent type impact coil embolization outcomes in extended follow-up of small-sized aneurysms (< 10 mm)?
Jeongjun Lee, Young Dae Cho, Dong Hyun Yoo, Hyun-Seung Kang, Won-Sang Cho, Jeong Eun Kim, Jusun Moon, Moon Hee Han
Neuroradiology.2018; 60(7): 747. CrossRef Mid-term 3T MRA follow-up of intracranial aneurysms treated with the Woven EndoBridge
SBT van Rooij, JP Peluso, M Sluzewski, HG Kortman, I Boukrab, WJ van Rooij
Interventional Neuroradiology.2018; 24(6): 601. CrossRef Usefulness of contrast-enhanced and TOF MR angiography for follow-up after low-profile stent-assisted coil embolization of intracranial aneurysms
Selcuk Akkaya, Onur Akca, Anıl Arat, Ahmet Peker, Sinan Balci
Interventional Neuroradiology.2018; 24(6): 655. CrossRef Usefulness of Vessel Wall MR Imaging for Follow-Up after Stent-Assisted Coil Embolization of Intracranial Aneurysms
S. Kim, M. Kang, D.W. Kim, J.-H. Choi
American Journal of Neuroradiology.2018; 39(11): 2088. CrossRef Imaging Parameter Optimization of 3D Phase Contrast-MRA to Reduce Susceptibility-artifact and Radiofrequency-shielding around the Intracranial Stent
Masato Kiriki, Wataru Jomoto, Takashi Ikeda, Noriko Kotoura
Japanese Journal of Radiological Technology.2018; 74(11): 1293. CrossRef In vitro comparison of intracranial stent visibility using various concentrations of gadolinium contrast agent under 1.5 T and 3 T MR angiography
Chen-Hua Chiang, Ying-Chi Tseng, Ai-Chi Chen, Yen-Lin Huang, David Yen-Ting Chen, Chi-Jen Chen, Yen-Kuang Lin, Hui-Ling Hsu
Journal of NeuroInterventional Surgery.2017; 9(4): 399. CrossRef Effects of Imaging Parameters on the Quality of Contrast-Enhanced MR Angiography of Cerebral Aneurysms Treated Using Stent-Assisted Coiling: A Phantom Study
Yoichiro Ikushima, Takashi Hashido, Yoshiyuki Watanabe, Tsukasa Doi
Magnetic Resonance in Medical Sciences.2017; 16(2): 146. CrossRef Usefulness of Non–Contrast-Enhanced MR Angiography Using a Silent Scan for Follow-Up after Y-Configuration Stent-Assisted Coil Embolization for Basilar Tip Aneurysms
N. Takano, M. Suzuki, R. Irie, M. Yamamoto, N. Hamasaki, K. Kamagata, K.K. Kumamaru, M. Hori, H. Oishi, S. Aoki
American Journal of Neuroradiology.2017; 38(3): 577. CrossRef Non-Contrast-Enhanced Silent Scan MR Angiography of Intracranial Anterior Circulation Aneurysms Treated with a Low-Profile Visualized Intraluminal Support Device
N. Takano, M. Suzuki, R. Irie, M. Yamamoto, K. Teranishi, K. Yatomi, N. Hamasaki, K.K. Kumamaru, M. Hori, H. Oishi, S. Aoki
American Journal of Neuroradiology.2017; 38(8): 1610. CrossRef PulseRider for Treatment of Wide-Neck Bifurcation Intracranial Aneurysms: 6-Month Results
Benjamin Gory, Alejandro M. Spiotta, Franscesco Di Paola, Salvatore Mangiafico, Leonardo Renieri, Arturo Consoli, Alessandra Biondi, Roberto Riva, Paul-Emile Labeyrie, Francis Turjman
World Neurosurgery.2017; 99: 605. CrossRef Follow-up of intracranial aneurysms treated with stent-assisted coiling: Comparison of contrast-enhanced MRA, time-of-flight MRA, and digital subtraction angiography
David Marciano, Sébastien Soize, Georgios Metaxas, Christophe Portefaix, Laurent Pierot
Journal of Neuroradiology.2017; 44(1): 44. CrossRef Follow-up assessment of coiled intracranial aneurysms using zTE MRA as compared with TOF MRA: a preliminary image quality study
Song’an Shang, Jing Ye, Xianfu Luo, Jianxun Qu, Yong Zhen, Jingtao Wu
European Radiology.2017; 27(10): 4271. CrossRef PulseRider Stent-Assisted Coiling of Wide-Neck Bifurcation Aneurysms: Periprocedural Results in an International Series
B. Gory, A.M. Spiotta, S. Mangiafico, A. Consoli, A. Biondi, E. Pomero, M. Killer-Oberpfalzer, W. Weber, R. Riva, P.E. Labeyrie, F. Turjman
American Journal of Neuroradiology.2016; 37(1): 130. CrossRef Fate of Coiled Aneurysms with Minor Recanalization at 6 Months: Rate of Progression to Further Recanalization and Related Risk Factors
J. P. Jeon, Y. D. Cho, J. K. Rhim, D. H. Yoo, W.- S. Cho, H.- S. Kang, J. E. Kim, M. H. Han
American Journal of Neuroradiology.2016; 37(8): 1490. CrossRef Contrast-Enhanced and Time-of-Flight MRA at 3T Compared with DSA for the Follow-Up of Intracranial Aneurysms Treated with the WEB Device
C. Timsit, S. Soize, A. Benaissa, C. Portefaix, J.-Y. Gauvrit, L. Pierot
American Journal of Neuroradiology.2016; 37(9): 1684. CrossRef Microwave spectrometry for the evaluation of in-stent neoatherosclerosis
G Arauz-Garofalo, L M Camacho-Puerma, A García-Santiago, J Tejada
Biomedical Physics & Engineering Express.2015; 1(3): 035202. CrossRef Assessing Blood Flow in an Intracranial Stent: A Feasibility Study of MR Angiography Using a Silent Scan after Stent-Assisted Coil Embolization for Anterior Circulation Aneurysms
R. Irie, M. Suzuki, M. Yamamoto, N. Takano, Y. Suga, M. Hori, K. Kamagata, M. Takayama, M. Yoshida, S. Sato, N. Hamasaki, H. Oishi, S. Aoki
American Journal of Neuroradiology.2015; 36(5): 967. CrossRef The Contribution of Common Surgically Implanted Hardware to Functional MR Imaging Artifacts
A.A. Desai, M.K. Strother, C.C. Faraco, V.L. Morgan, T.R. Ladner, L.M. Dethrage, L.C. Jordan, M.J. Donahue
American Journal of Neuroradiology.2015; 36(11): 2068. CrossRef Use of Dual Energy Computed Tomography Imaging to follow up Stent-assisted Coil Embolization
Toshiyuki Onda, Daisuke Sasamori, Yasuyuki Yonemasu, Yuji Hashimoto, Osamu Honda, Akira Takahashi, Tadashi Nonaka, Masahiko Daibou
Japanese Journal of Neurosurgery.2015; 24(9): 614. CrossRef Time-of-Flight Magnetic Resonance Angiography for Follow-Up of Coil Embolization with Enterprise Stent for Intracranial Aneurysm: Usefulness of Source Images
Young Dae Cho, Kang Min Kim, Woong Jae Lee, Chul-Ho Sohn, Hyun-Seung Kang, Jeong Eun Kim, Moon Hee Han
Korean Journal of Radiology.2014; 15(1): 161. CrossRef Will Fluoroscopic Follow-up after Stent-Assisted Coiling of Cerebral Aneurysms Provide Information on Recanalization?
Hyun Ho Oh, Cheolkyu Jung, Tae Hong Lee, Bae Ju Kwon, Young Kim, Kyu Chang Lee
Interventional Neuroradiology.2014; 20(6): 693. CrossRef Solitaire AB Stent-Assisted Coiling of Wide-Necked Intracranial Aneurysms
Benjamin Gory, Joachim Klisch, Alain Bonafé, Charbel Mounayer, Remy Beaujeux, Jacques Moret, Boris Lubicz, Roberto Riva, Francis Turjman
Neurosurgery.2014; 75(3): 215. CrossRef Artificial Luminal Narrowing on Contrast-Enhanced Magnetic Resonance Angiograms on an Occasion of Stent-Assisted Coiling of Intracranial Aneurysm:In VitroComparison Using Two Different Stents with Variable Imaging Parameters
Jee Hyun Seok, Hyun Seok Choi, So-Lyung Jung, Kook-Jin Ahn, Myeong Jin Kim, Yong Sam Shin, Bum-soo Kim
Korean Journal of Radiology.2012; 13(5): 550. CrossRef
|