Initial Experience with Neuroform EZ in the Treatment of Wide-neck Cerebral Aneurysms
Erwin Zeta Mangubat, Andrew Kelly Johnson, Kiffon M. Keigher, Demetrius Klee Lopes
Neurointervention. 2012;7(1):34-39.   Published online 2012 Feb 29     DOI: https://doi.org/10.5469/neuroint.2012.7.1.34
Citations to this article as recorded by Crossref logo
Bifurcated Aneurysm Location Predicts In-Stent Stenosis After Neuroform-EZ Stent-Assisted Coiling for Intracranial Aneurysm
Wei You, Junqiang Feng, Huijian Ge, Hengwei Jin, Peng Liu, Youxiang Li, Yuhua Jiang, Xinke Liu
Frontiers in Neurology.2022;[Epub]     CrossRef
Two-center experience with Neuroform Atlas stent-assisted coil occlusion of broad-based intracranial aneurysms
Gamze Arslan, Volker Maus, Werner Weber, Ansgar Berlis, Christoph Maurer, Sebastian Fischer
Neuroradiology.2021; 63(7): 1093.     CrossRef
A Comparison of Safety and Effectiveness Between Wingspan and Neuroform Stents in Patients With Middle Cerebral Artery Stenosis
Kai Zhou, Yuan Cao, Xiao-Hui He, Zhong-Ming Qiu, Shuai Liu, Zi-Li Gong, Jie Shuai, Qing-Wu Yang
Frontiers in Neurology.2021;[Epub]     CrossRef
Initial multicentre experience using the neuroform atlas stent for the treatment of un-ruptured saccular cerebral aneurysms
Jin Wook Baek, Sung-Chul Jin, Jung Hoon Kim, Min Wook Yoo, Hae Woong Jeong, Jung Hwa Seo, Ji Yeon Han, Young Jin Heo, Sung Tae Kim
British Journal of Neurosurgery.2020; 34(3): 333.     CrossRef
Simultaneous neck coverage and branch preservation using the proximal portion of a self-expandable open-cell stent for embolization of distal internal carotid artery aneurysms: multi-center, long-term results
Hyon-Jo Kwon, Seung-Hoon You, Jeong-Wook Lim, Hyoung Soo Byoun, Bon-Sub Gu, Su-Hee Cho, Hyeon-Song Koh
Neuroradiology.2020; 62(7): 883.     CrossRef
Treatment of acute thrombosis during stent-assisted coil embolization of ruptured proximal posterior inferior cerebellar artery aneurysm
Guangwen Li, Tonghui Liu, Naidong Wang, Yong Zhang
Brain Circulation.2020; 6(2): 130.     CrossRef
NeuroForm Atlas Stent-Assisted Coiling: Preliminary Results
Michelle F M ten Brinck, Joost de Vries, Ronald H M A Bartels, J André Grotenhuis, Hieronymus D Boogaarts
Neurosurgery.2019; 84(1): 179.     CrossRef
Neuroform EZ Stenting for Symptomatic Intracranial Artery Stenosis: 30 Days Outcomes in a High-Volume Stroke Center
Haowen Xu, Tao Quan, Osama O. Zaidat, Dapu Chen, Zibo Wang, Yongjie Yuan, Baojun Yan, Hong Lu, Sheng Guan
Frontiers in Neurology.2019;[Epub]     CrossRef
The Interference Phenomenon of Microcatheters in the Jailing Treatment for Internal Carotid Artery Side Wall Aneurysms with an Open Cell Stent System
Minwook Yoo, Sung-Chul Jin, Seung-Hwan Kim, Byeong-Sam Choi, Hae Yu Kim, SungJun Lee, Sung Tae Kim, Hae Woong Jeong
Journal of Cerebrovascular and Endovascular Neuros.2016; 18(4): 363.     CrossRef
Use of Triple Microcatheters for Endovascular Treatment of Wide-Necked Intracranial Aneurysms: A Single Center Experience
Young Dae Cho, Jong Kook Rhim, Hyun-Seung Kang, Jeong Jin Park, Jin Pyeong Jeon, Jeong Eun Kim, Won Sang Cho, Moon Hee Han
Korean Journal of Radiology.2015; 16(5): 1109.     CrossRef
Modified coil protection for proper coil frame configuration in wide-necked aneurysms
Young Dae Cho, Jong Kook Rhim, Jeong Jin Park, Jin Pyeong Jeon, Hyun-Seung Kang, Jeong Eun Kim, Won-Sang Cho, Moon Hee Han
Neuroradiology.2015; 57(7): 705.     CrossRef
Advances in Endovascular Approaches to Cerebral Aneurysms
Travis M. Dumont, Jorge L. Eller, Maxim Mokin, Grant C. Sorkin, Elad I. Levy
Neurosurgery.2014; 74(Supplement): S17.     CrossRef
AN INTERNET-BASED METHOD TO ELICIT EXPERTS’ BELIEFS FOR BAYESIAN PRIORS: A CASE STUDY IN INTRACRANIAL STENT EVALUATION
Leslie Pibouleau, Sylvie Chevret
International Journal of Technology Assessment in .2014; 30(4): 446.     CrossRef
Analysis of flow changes in side branches jailed by flow diverters in rabbit models
Juan R. Cebral, Marcelo Raschi, Fernando Mut, Yong-Hond Ding, Daying Dai, Ramanathan Kadirvel, David Kallmes
International Journal for Numerical Methods in Bio.2014; 30(10): 988.     CrossRef
Neuroform Intracranial Stenting for Aneurysms Using Simple and Multi-stent Technique Is Associated With Low Risk of Magnetic Resonance Diffusion-Weighted Imaging Lesions
Robert S. Heller, Venkata Dandamudi, Daniel Calnan, Adel M. Malek
Neurosurgery.2013; 73(4): 582.     CrossRef