Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 81 Warning: fopen(/home/virtual/neurointervention/journal/upload/ip_log/ip_log_2024-04.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 83 Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 84 Ferromagnetic Artifact Due to Metallic Embolic Fragment after Endosaccular Coil Embolization: A Case Report.
Neurointervention Search

CLOSE


Neurointervention 2006;1(1):73-75.
Ferromagnetic Artifact Due to Metallic Embolic Fragment after Endosaccular Coil Embolization: A Case Report.
Cheolkyu Jung, Seung Hun Sheen, Jae Hoon Cho, Bae Ju Kwon, Moon Hee Han
Department of Radiology, Seoul National University College of medicine, Seoul, South Korea. hanmh@radcom.snu.ac.kr
Abstract
We report one case showing the ferromagnetic artifact in the cortical area of brain after coil embolization of cerebral aneurysms. There were minimal ferromagnetic artifacts around coil mass on the MR after endosaccular coil embolization for intracranial aneurysm. But we were not able to find the report about the ferromagnetic artifact in the cortical area after coil embolization by means of a pubMed search.
Key Words: Aneurysm; Coil embolization; Artifact; Magnetic resonance (MR)